If you modify a part in a part document, or modify, move, delete, etc. a part in a product document and the measure is impacted, it will be identified as not up-to-date in the specification tree. This section deals with: |
|
|
Design Mode measures and, in Visualization Mode, measures on products selected in the specification tree only are associative. |
|
|
Open the
AssociativeMeasures.CATPart from the In ENOVIA DMU, insert the CATPart. |
|||||||||||||||||||||||||||||||||
|
|
Automatic Update
|
|||||||||||||||||||||||||||||||||
|
|
|||||
|
|
|||||
|
Notes: In a part document, you must also select the
Automatic Update option button in
In a product document, if you edit a part, any measures will be automatically updated when you activate the product. When you open a product document, measures are not automatically updated even if the Automatic update in product check box is selected in Tools > Options > Parameters and Measure, Measure Tools tab. For example, if you save a document in which measures are not up-to-date and then re-open the document, measures remain in the not up-to-date status even if you selected the automatic update check box in Tools > Options.
|
|
|
Open the Update_Measure.CATProduct
The measure is to be updated, a tornado is displayed.
|
|
Activate a product in the specification tree
The measure update operation is launched. The tornado is no longer displayed.
When done, close your product without saving changes.
|
|
Notes:
|
In a part, Measure Between, Measure Item and Measure
Inertia measures are now integrated into the Part Design Update mechanism.
An Update Diagnosis message is displayed if during Part update operation, a
related-measure problem is identified.
This message lets you solve the problem editing or deleting the measure
|
|
|
|
|
Notes:
|
Measures are no longer valid if links are not resolved. This happens if:
You delete an item on which a measure is made
You switch to visualization mode or open a document in
visualization mode.
For example, your measure is made on a face in design mode, you save the
document and then re-open it in visualization mode.
Measures that are no longer valid are identified in the
specification tree by the measure icon plus an exclamation mark, for
example
and, for Measure
Between and Measure Item measures, the measure itself changes color.
![]() |
In a part document, Measure Between, Measure Item and Measure Inertia measures are integrated into the parent-child mechanism. If you delete items on which measures are made, the Delete dialog box appears letting you delete measures at the same time. Associated measures are highlighted in the specification tree.
|
|
Similarly, if you delete measures, the Delete dialog box lets you delete the measured items provided they are exclusively used for the measures (Delete exclusive parents option).
|
|
|
Measures made prior to Version 5 Release 6 are not
associative and therefore cannot be updated. These measures are
identified in the specification tree by the measure icon plus a lock, for
example
.
Visualization Mode measures and measures on cgr files
made in the geometry area are not associative and therefore cannot be
updated. These measures are identified as above:
.
Only products selected in the specification tree in Visualization Mode
can be updated.
Measures made in Picking point, Picking axis, Intersection and Center of 3 points selection modes are not associative.
Inertia measures made on a multiple selection of items are not associative.
In the Drafting, Generative Structural Analysis and Advanced Meshing Tools workbenches, measures are done on-the-fly and are not persistent. This means that they are not associative.
Measure does not support update management with VPM V4.
Measures loaded from VPM V4 can be not up to date, if this is the case, use the Force measure update from the contextual menu accessible via a right-click on measure container in the specification tree.
![]() |
![]()