List of Detected Return Codes

The CATDUA V5 capabilities are to check structural data within a CATProduct, CATPart, CATDrawing, CATAnalysis, CATMaterial, CATProcess, and to clean (modify) the data structure.

This batch is useful in the following situations:

  • Before recovering external data.
  • Before starting a new V5 release.
  • Broken links when opening products.
  • Incidents when updating a component (e.g. sketch update).
  • The Links window appears: some documents have been found but have no references.
  • Performance problems when opening a product (because of lost links).

This section provides the exhaustive list of return codes that can be detected by the CATDUA V5 batch. To see the cleaner rules corresponding to any of these return codes, a license belonging to the domain of the return code is required. For a full description of each return code, refer to Table of Detected Return Codes.

Priority Levels

Priority Level Legend:

(1)  Priority One Return Code: Cleaning action may lead to data deletion.
(2)  Priority Two Return Code: Cleaning action may lead to data modification (without deletion).
(3)  Priority Three Return Code: Unimportant error. Cleaning action with minor impact on data.
(*) This symbol means that the rule is not executed on a document coming from a PDM system (ENOVIAVPM, ENOVIA LCA).
  Below is the list of categories that will be detailed:
 

Detected return codes

  1. Object Specs Modeler

Category Code Meaning Cleaner Action

DOC: linked document (container root)

DOC_1 (2)

Non typed document in a link Types the document in the link
DOC_3 (2) Missing links Updates the link counter
DOC_4 (3) Ghost links Updates the link counter
DOC_5 (2) Destroyed links Re-builds the missing link
DOC_6 (3) Applicative containers are lost Adds the empty stream
DOC_8 (3) Bad performance when opening a document due to an invalid link counter Deletes the link that does not appear to the end user but exists in table of inter-document links and compacts the table
DOC_9 (3) The CATPart cannot be updated Puts the data contained in all federators into one federator and deletes the empty federators
DOC_10 (1) Some applicative containers have the same user id Merges all data found on all containers into a single container
DOC_11 (3) Link to a useless CATPart when running the File > Send To command in a CATPart Deletes the meaningless repository containing no input or inputs that are no more pointed
DOC_12 (1) Cannot open a document Delete the corrupted storages
DOC_14 (1) A document cannot be opened and there are some OSM ERRORS such as OSM_RE001 If it is a section plane container or a CATCollabCont container, then it is physically removed from the document
DOC_15 (3) Selection/De-selection is very slow Removes the empty and useless containers
CAT: Catalog CAT_0 (2) A feature catalog has no name Removes the link to this catalog
CCL: Component Catalog CCL_0 (3) The name of the description and of the keyword are different Renames the description
CCL_1 (3) The same chapter appears with a name in the specification tree and with another name in the definition list Renames the chapter
CCL_2 (3) When a chapter's keyword is deleted, some internal data remain in descriptions Removes the useless internal data
CCL_4 (3) The link between a description's keyword value and its chapter's keyword might be broken Re-links the keyword value to its keyword
CCL_5 (2) Chapters cannot be viewed in the Catalog Editor Creates the missing description pointing to the chapter under the root chapter
CCL_6 (1) Ghost link when running the File > Send To command Deletes the corrupted feature with invalid reference on a startup
CCL_7 (1) A Part Family still exists even though all the descriptions have been deleted. The synchronization fails Deletes the reference after deleting the last related description
CCL_8 (1) A family cannot be dragged and dropped. Deletes the description of the family which points to its parent chapter
CCL_9 (1) When running the Edit >Links... command on catalogs where the Master Model has been isolated, the link with the Master Model is not displayed. Repairs the Master Model's isolation.
EXT: External Link EXT_0 (3) A link still exists to a pointing document due to an unused extension feature Deletes the link, the document needs to be updated
EXT_1 (3) A material is lost when opening a CATProduct Merges all the data found on all extensions into a single container
EXT_2 (3) Ghost links when opening a CATProduct The reference of an extension is not in the same document that the reference of its base feature (probably after a replace)
HIE: Hierarchy HIE_3 (3) A product instance has too many sub-products Deletes the extra sub-products and product instance is synchronized
HIE_5 (3) A change of reference is made during save as operation when a private component cannot find its reference and error DOC_3 may reappears Fixes Error DOC_3 completely
HIE_6 (1) The model cannot be updated. Some assembly data (constraints) are invalid Deletes the invalid connection
HIE_7 (1) Ghost links when running the File > Send To command in a CATPart Deletes all the ASM products instantiated in the PrtCont container of the CATPart
HIE_8 (2) None in phase 1, as other links are expected between the two documents so the File > Desk..., File > Send To, and Edit > Links... command behave as expected Re-routes the links in error in the Local Reference structure (internal links)
UPD: Update UPD_0 (2) The update cycle on the object is not visible/cannot be edited Unsets the link to itself (break the cyclic dependency)
UPD_2 (2) Update status propagation problem. Some data which should not be up-to-date are shown as up-to-date Increments the feature's update stamp
ENV: Environment ENV_1 (3) In the Specs Modeler domain, DUA errors are generated on a given document depending on the machine or level used. User or Admin must install the correct files in the Runtime View.
  1. Product Structure

Category Code Meaning Cleaner Action
BRK: Broken Object BRK_0 (1) Broken objects are not aggregated Deletes the objects
  BRK_1 (1) A feature has lost its StartUp link but an orphan feature has a valid link to an instance reference Retrieves the orphan feature
LIF: Product Lifecycle LIF_2 (3) Some objects cannot be accessed from the root product Deletes the objects
LIF_4 (3) (*) Non removed objects still exist in the CATProdCont container Deletes the objects
LIF_7 (3) Non removed connections still exist in the CATProdCont container Deletes the objects
LIF_8 (3) (*) Non removed connectors still exist in the CATProdCont container Deletes the objects
LIF_9 (3) Non removed product bag reps still exist in the CATProdCont container Deletes the objects
LIF_12 (3) Ghost link to another document Unsets the _ToProxy attribute
LIF_13 (1) Ghost link when running the File > Send To command Deletes the internal object (proxy) with the invalid link
AGG: Aggregation AGG_1 (1) An aggregated object does not know its aggregating object Deletes the aggregation
AGG_2 (2) Ghost links, the view cannot be deleted, the Copy > Paste command does not work Updates the aggregation link
AGG_3 (2) A father-son link between an instance and the product is deleted, which prevents the destruction of the instance Uses the CATSpecSetFather Spec service to reset the link
AGG_4 (2) A constraint is broken when making a product flexible. Puts the connector is on the right product attribute, and instantiates it on all the referencing documents
AGG_5 (1) Ghost link when running the File > Send To command in a CATPart Deletes the useless PUBLISHING features
ATT: Rule Attribute ATT_2 (2) Unwanted modified status of the documents after an update Deletes the erroneous internal attribute
ATT_3 (1) An unused attribute (activrep) is valuated Unsets the attribute
ATT_4 (2) The update stamp of the position attribute is incorrect Updates the update stamp
ATT_6 (2) An external reference is up-to-date whereas its target has changed Sets the link as not up-to-date and initializes the time stamp list
ATT_11 (1) Ghost link when running the File > Send To command Deletes the overloaded attribute in the Product instance
ATT_12 (2) Synchronization problem of an external parameter pointing to a parameter publication Keeps only one pointing attribute valuated, with priority given to the resolved one
ATT_13 (2) An External Reference is seen as synchronized whereas the referenced geometry has changed Makes the connector as not up-to-date then updates it
ATT_14 (2) A CATPart is seen as modified after being inserted in a CATProduct When UPD_2 cleaning is done, an additional action is needed on the connectors: the synchronization status is reset to force their update
UAQ: Product structure - Unexpected Attribute Quality UAQ_1 (3) The quality on a publication instance is different from the publication startup Changes the quality from "neutral" to "in"
UAV: Product structure - Unexpected Attribute Value UAV_0 (2) Illegal position attribute Sets the position matrix to the nearest isometric matrix if found, or to identity
UAV_1 (1) Incorrect overloading of a position attribute Switches to flexible products
UAV_2 (3) A connector points to an invalid object Sets the link correctly
UAV_3 (1) A constraint is not in the right container Deletes the constraint
UAV_4 (3) There are blanks in the component's list Deletes the blanks
UAV_5 (2) A connection instance and a reference point have different connectors (by publication) Synchronizes the connection
UAV_6 (3) A connection points to an invalid object Synchronizes the connection
UAV_7 (2) A Product instance has an overloaded contextuality Synchronizes the Product instance
UAV_8 (2) A product has many representations (no visualization when opening it) Synchronizes the Product instance
UAV_9 (3) A connector has incorrect connections Deletes the incorrect connections
UAV_10 (3) (*) A part document poins to useless components Empties the _component attribute
UAV_11 (3) The Shape Connector attribute of the connector points to an invalid document Resets the Shape Connector attribute
UAV_12 (3) (*) The _TechnoLinkAttr attribute is wrong Resets the _TechnoLinkAttr attribute
UAV_14 (3) The same publication appears several times in the specification tree Removes all the duplicate publications but one
UAV_15 (2) (*) The PUBLISHING_Pointage, PUBLISHING_Etiquette and/or PUBLISHING_PubName attributes are affected to the instance instead of the reference Transfers the PUBLISHING_Pointage, PUBLISHING_Etiquette and PUBLISHING_PubName attributes from the instance level to the reference level
UAV_16 (2) The instance externals are locally set Resets the instance externals
UAV_18 (2) (*) No shape representation for a part reference, or the shape representation of a reference points to another part shape Makes the shape representation point to the own part shape
UAV_19 (2) (*) A contextual link stays as not up-to-date even after an update Unsets the contextual link
UAV_21 (1) Discrepancy between the number of part publications in the assembly and the number of publications when opening the part separately Resets the corrupted list of publications according to the value of this reference
UAV_22 (1) Error when performing an update Deletes the invalid reference connection
UAV_23 (2) (*) A publication is wrongly seen as up-to-date Updates the time stamp of the parameter if the publication points to a parameter
UAV_27 (2) Impossible to select a publication under a Product instance Runs a SmartSynchro from the publication reference and restores the association
UAV_29 (2) Publications pointing a parameter are no longer resolved Re-evaluates the publications using an old protocol with the new one
UAV_30 (1) Connections are lost in a product assembly that has been made flexible Removes all the connection instances of the connections which reference has already been instantiated
UAV_31 (2) A contextual link is seen as connected (OK) in the "Define contextual Links " command whereas it is not possible to resolve it and to update the contextual geometry Fixes the PRDCTXINPUT feature so that it points to the same context (i.e. the Product instance) as the one pointed to by its PRDCTXREPO
UAV_32 (2) When a parameter value is changed, the publication may show a wrong update status and may be seen as up-to-date Sets the time stamp of the parameter under the publication attribute (_ModifiersTS) if the publication points to a parameter
UAV_33 (2) Some publications cannot be removed. No action is possible on such publications Deletes the useless publications
UAV_34 (2) Part Number conflict in the assembly Automatically detects the Part Number conflict and renames objects accordingly
Problem with Instance’s feature unique identifier(UUID) When there are product assembly parts with same UUID's, an error message appears informing the same.You can manually fix them by recreating the Instance using Replace or Insert operations.
UAV_35 (2) When inserting a part in product, the part is transferred to the No Show space Resets the Show attribute to CATShowAttr and the part is modified
UAV_36 (2) Invalid position of CATParts in Vizualization mode before update. Recreation of Proxy Object
UPG: Upgrade UPG_0 (3) Invalid multi-representation (V5R2 model) Cleans the multi-representation
UPG_1 (3) (*) After reordering the publications or deleting a part, the publications reference a wrong geometry Cleans this attribute by a new Spec relation without relative mode
SYN: Synchronization SYN_1 (3) Multi-instantiation of a reference by the synchronization Deletes/adds the feature
SYN_2 (1) The PRDBAGREP attribute of the ASM product does not reference the PRDBAGREP of the reference ASM product Resets the BagRepsList attribute of the ASM product
HIE: Hierarchy HIE_4 (1) An internal object (connector) has an inconsistent state and keeps an instance-reference link to a useless document Removes the connector
NUM: Numbering NUM_0 (3) A warning is displayed when opening a CATProduct Removes the phantom numbering
  1. Mechanical Modeler

Category Code Meaning Cleaner Action

BST: BackUp Start Up

BST_1 (3) The BackUp StartUp is not declared in the CAA mechanical feature Declares the BackUp StartUp
LIF: Product Lifecycle LIF_1 (1) The size of the CATPart is abnormally huge compared to the number of elements and unused elements (Geometrical feature) Deletes the unused elements, the part is the same but smaller. The removal of unused elements might help to remove ghost links
LIF_3 (3) No visibility except the size of the CATProduct (when removing constraints) Deletes the unused elements, the document is the same but smaller
LIF_5 (3) Non referenced elements in the CATSelSetsCont container Deletes the elements
LIF_10 (3) Non pointed or useless proxy objects Deletes the useless proxy objects
LIF_11 (3) An internal object is unused in the applicative container Deletes the useless object
LIF_20 (1) Ghost link when running the File > Send To > Directory command which prevents the drawing release system to run. Drawings are the customer's final product. Deletes human features if no aggregating manikin can be found.
LIF_21 (2) Ghost link when running the File > Send To command. Aggregates the Delete_To connector under the Connectors family and synchronizes it so that it points to the correct document
MMR: Mechanical Modeler MMR_0 (1) The 3 reference planes are corrupted Restores valid reference planes
MMR_1 (2) A Shape representation is not pointed to by a product Resets the link
MMR_2 (2) No Main tool in the part Creates a default Main tool
MMR_4 (2) Wrong visualization behavior and unexpected restrictions occur when trying to move an instance elsewhere in the part Reorders or creates the missing set under the part
MMR_5 (2) No In Work object in the tree or incorrect visualization Sets the part body as In Work object
MMR_6 (3) The standard for layers and layer filters is not available in the CATPart document Creates the standard for layers and layer filters
MMR_8 (2) Some datum features contain wrong data that prevents the save operation in ENOVIA Data of those datum features are modified to be managed correctly.
MMR_12 (2) The V5 part cannot be imported in 3DExperience through FBDI. A pointed document is erroneously referenced and is not visible in Edit > Links or File > Desk. The document can be imported using FBDI or DBDI tools.
MMV MMV_1 (3) Invalid graphic property on the part Deletes the invalid property
MMV_2 (3) An invalid graphic property remains in the model even after a removal Restores correctly the dress-up properties
MMV_3 (3) Wrong attribute values on the part body of a CATPart created in V5R10 Deletes the wrong attribute names
MMV_6  (3) If the action Change Part Body is done recursively, the application hangs when you try to update. On the current PartBody, the views attributes are cleaned by deleting the duplicate values. On the other bodies, the views attributes are unset. The application will not hang during an update.
MGN: Mechanical Generic Naming (topology) MGN_0 (2) There is more than one topological result Deletes the extra results
MGN_3 (2) The feature has an invalid update state Restores a valid state
MGN_4 (3) The generic naming of the BRep features creates duplicated data Removes the duplicated data
MGN_5 (3) The feature keeps useless synchronization data Removes the useless synchronization data
MGN_6 (1) The size of a CATPart on disk is abnormally huge Removes the useless Mechanical Modeler data
     
MGN_7 (2) Some cells in a datum feature cannot be selected Adds a naming to the cells
MGN_8 (1) Setting applicative attributes and colors using a dedicated CAA interface takes too much time Deletes the invalid BRep features for colors and applicative attributes
MGN_9 (1) The CATDUA V5 (LIF_1) deletes a publication in the part or in a non aggregated BRep feature Deletes the invalid BRep feature and re-plugs the publication to the equivalent BRep access
MGN_10 (3) Bad performances when updating part containing big import features Deletes the useless data
MGN_11 (2) Some BRep features on an axis, a plane and an extremity created before R11 may be in update error but no error is generated. Thus, they are pointing to a no more existing geometry Puts the BRep feature in a not updated state. The update will generate an update error which will allow the correction of the BRep feature
MGN_12 (3) The document size is too big Compresses the BRep feature to minimize the size
MGN_13 (2) Some BRep features are in error Tries to retrieve the lost specification.
MGN_14 (3) The import feature has wrong data. Update the document after the manual modifications.
MGN_17 (2) Stream of CATPart used a short (16 bits) for a particular information until CATIAV5R19 included, which leads to problems with very large models. This information is streamed on an integer (32 bits) since CATIAV5R20.
Very large models, older than CATIAV5R20 and containing big feature, with more than 65536 faces gets incoherent information.
Some features could be as non-updated.
The document needs to be updated.
MGN_18 (2) Some features BRep have wrong internal orientation. An update is necessary.
The document needs to be updated.
MTR: Mechanical Tools MTR_0 (2) The tool's result is not correctly plugged Plugs the result
MTR_1 (3) The body's reference is lot Sets the reference to Start-Up
MTR_2 (2) Some Shape features are not correctly plugged Re-plugs the Shape features
MTR_3 (3) The VisuOnOff attribute is not correctly valuated Resets the attribute
MFT: Shape Features Tools MFT_0 (2) The active/inactive status does not match the attribute structure Resets the attribute
MFT_1 (1) An inactive feature stores the result of the previous feature Removes the result in the inactive feature
MFT_2 (1) The result of a Shape feature is valuated with the result of the previously active feature Regenerates the result
MFT_3 (1) The attribute of an inactive Shape feature is not saved or is not set Regenerates or re-evaluates the attribute
GST: Generative Surface Tool GST_0 (2) Unidentified object (broken icon) called Rolling Offset when opening a CATPart. The startup is lost for a GSM Rollng Offset Re-plugs the startup
GSD: Generative Shape Design GSD_0 (3) Unused aggregated feature Deletes the useless feature
GSD_1 (1) The reference planes are set as datum or as independent specifications Corrects the Visualization Graph attribute, aggregates the moved reference plane in the current Open Body and creates a new reference plane
GSD_2 (2) The orientation might be inverted when updating a CATPart Modifies the axis system attribute with respect to the new algorithm
GSD_4 (2) Ghost link in the CATPart Removes the link
GSD_5 (1) Corrupted CCP link No cleaning action for this error
CTX: Context CTX_1 (3) (*) A part has multiple contexts Deletes the extra contexts
CST: Constraints CST_1 (2) Non-typed constraint Types the constraint
CST_2 (2) Wrong attribute quality Modifies the quality
CST_3 (1) Some attributes on constraints are not valuated Deletes the constraints
CST_4 (1) Ghost link in a CATDrawing because of an invalid "blocs" attribute in a constraint Valuates the "blocs" attributes of the constraint
SSS: selection Set SSS_1 (3) The Selective Loading of documents with a selection sets containing elements outside its scope can lead to an unexpected behavior Not fixable
UDF: User Feature UDF_0 (2) (*) A user feature has an invalid input Re-plugs the input
       
  1. Assembly

Category Code Meaning Cleaner Action
ASD: Assembly Design (constraints) ASD_0 (1) The start up of constraint is not found Loads the AsmCst.feat catalog
ASD_1 (1) Isolated constraint Deletes the constraint
ASD_2 (1) The constraint is not correctly stored Deletes the constraint
ASD_3 (2) The constraint type is lost Restores the constraint type
ASD_4 (2) Wrong attribute quality Modifies the quality
ASD_5 (1) Inconsistency between the feature catalog in V5R12 GA and the catalog in upper versions or service packs Deletes the corrupted Fix Together and replaces it by a new one
ASD_6 (1) A Fix Together has no parent Deletes the corrupted Fix Together
ASD_7 (2) A constraint attribute is not correctly valuated Sets a correct value for the attribute
ASD_9 (3) Constraints cannot be reordered because of unused sets Deletes the unused sets of constraints
ASD_10 (2) Some constraints are displayed in the 3D window but not in the specification tree Aggregation problem: the Connection does not know the ConstraintASM, but the ConstraintASM knows that the Connection is its parent
ASD_11 (1) Unusable constraints cannot be deleted Deletes the corrupted constraints
ASD_12 (3) Some constraints are not visible in the specification tree "under construction"
ASD_13 (3) The Save as Frozen (only one product) command does not work Deletes the unexpected SVVersion and the CATSpecXMan attributes from the CATMechProdCont container
AFI: Assembly Feature AFI_1 (3) An Assembly feature points to the wrong inputs Corrects the wrong links
AFI_2 (2) An instance of a Reuse Pattern feature points to a wrong document, probably because of a problem when synchronizing the feature Unsets the pointing attribute on the instance
AFI_3 (3) Ghost links when running the File > Send To command in the CATProduct Plugs the instance to the right reference and resets/synchronizes it
  1. Analysis

Category Code Meaning Cleaner Action
SAF: Features (Spec view) SAF_2 (2) The feature has no explicit image Creations an explicit image
SAF_3 (1) The feature contains an invalid explicit data Deletes the data
SAF_4 (2) Missing links between the mesh and the physical data attached to the mesh Creates the appropriate links
SAF_5 (2) Some nodes have a wrong activity status Corrects the status
SAF_6 (2) Missing feature in the assembly model Creates the missing feature
SAF_7 (2) The model can be neither solved, nor saved Detects the explicit entities with a duplicate tag number and corrects their tag number
SAF_8 (2) Surface group of neighborhood does not goes out-of-date, when the corresponding father mesh part goes out of date. The link between father mesh part and surface group under it is recreated.
SAF_9 (2) Analysis Set is not getting updated. Missing parent of the Analysis Set is added.
  1. Sketcher

Category Code Meaning Cleaner Action
SCS: Sketcher Constraint SCS_0 (2) The sketch solving result is not stable. Geometries can move when editing a sketch Adds the missing Help parameter to the constraint
SCS_1 (2) Ghost links on 2D constraints. The attributes of the 2D constraints reference external documents. Removes the invalid reference to the pointed document
SKT: Sketcher SKT_0 (1) The sketch has no father Deletes the sketch
SKT_24 (3) The Fsur of the _FtrList must be referenced Deletes the Fsur
SKT_25 (3) Wrong sketch version Changes the version
SKT_26 (2) Ghost link when opening a CATPart Re-plugs the geometry with ghost links on their details/dittos in the CATDrawing to their startups in the current CATPart
SKT_27 (2) Some output features are badly aggregated Replaces the output in the dedicated node of the sketch they belong to
SKT_28 (2) Sketches created on a partiular level might encounter problems when updating use edges. Corrects the tolerance problem so that use edges are correctly updated after modifying the sketch.
SMG: Solve Manager (Sketch object) SMG_4 (2) The ImportedGeom attribute size must be the same as the number of operators Resizes the list
SMG_5 (2) The ImportedGeom attribute has no operator Revaluates the attribute
SMG_6 (2) Mismatched ImportedGeometry attribute Revaluates the attribute
SMG_9 (2) Invalid number of constraints Revaluates the attribute
SMG_16 (2) The Solve Manager is not impacted by the update Sets the constraint attribute to neutral
SMG_17 (2) Invalid OutputGeoms attribute Revaluates the attribute
IGS: Imported Geometrical Set IGS_0 (3) Invalid phantom operator Deletes the operator
SKS: Sketch Support SKS_0 (2) The absolute axis of a sketch or of a sub-element cannot be used to create a feature Puts the absolute axis feature out of date
SKS_1 (2) The update cycle is not detected Changes the structure of the feature to detect the cycle
SKS_2 (2) O point, H and V vectors of the absolute axis of the sketch are missing from the specification tree and are not visualized Recreates the missing elements of the absolute axis of the sketch
SKS_3 (1) Data can not be imported in 3DEXPERIENCE using FBDI. Remove a non aggregated SketchSupport.
CRV: Curve CRV_0 (2) End points are not found on the curve Adds the missing end points
CRV_1 (3) Wrong update result because the update propagation is wrong Sets the feature attributes to sp_NEUTRAL instead of sp_IN
CRV_2 (2) Ghost link when running the File > Send To command Sets the invalid "Start Point" attribute and "End Point" attribute with the new limit points
CRV_3 (2) Ghost link when running the File > Send To command  
CRV_4 (2) A circle visible on previous releases is now invisible in the current release Forces the open curve to be closed
CRV_5 (1) An ellipse invisible in previous releases is now visible Deletes the ellipse which was previously invisible
  1. Material

Category Code Meaning Cleaner Action
MAT: Material MAT_1 (1) A part has more than on material container Deletes the extra containers
MAT_2 (3) The material container has orphan elements Deletes the orphan elements
MAT_3 (2) A material is not correctly visualized Reapplies the material. Note that this error might be impossible to fix if the material cannot be retrieved (for example, if the material is located in an inaccessible material catalog)
MAT_4 (3) Invalid material link Deletes the link
MAT_5 (2) The material parameter contains incorrect data Modifies the material parameter
MAT_6 (2) Ghost link in a material Reroutes the link to a correct material link
MAT_7 (3) Ghost link when running the File > Send To command A material is located in the wrong container (not the material container) and this may lead to ghost links. This material is unused and should be destroyed
MAT_8 (2) Ghost link when running the File > Send To command Corrects the advanced materials
  1. Drafting

Category Code Meaning Cleaner Action
ABM ABM_0 (1) A link to the Bill of Material exists even though the drawing is empty. This link is displayed when running Edit > Links even if the drawing is empty and it cannot be deleted. Deletes the Bill of Material
ACA: Drafting ACA_0 (2) File > Send To command shows a Ghost link. A pointed document is erroneously referenced in File > Send To and is not visible in Edit > Links or File > Desk The link is unset
DAS: Drafting Axis System DAS_0 (1) When running the File > Send To command, an unrelated document can be pointed to by a drawing An object managing the view axis origin has an invalid link to a 3D document
DBA DBA_0 (2) Wrong link in a default feature Deletes the link
DDU: Drafting Dress-up DDU_0 (2) A useless data (connector, 3D feature) references another document (CATPart) Deletes the data and its links to other documents
DDU_1 (2) A CATDrawing contains an invalid link to another drawing Deletes the invalid link
DDU_2 (1) Ghost link in a CATDrawing Deletes the axis lines, center lines or thread that are directly under the DrwCont container
DOB: Drafting Operator Breakout DOB_0 (1) A CATDrawing with isolated views still has some links to 3D parts/product when running the File > Send To command Deletes the link
DOP: Drafting Operator Projection DOP_0 (1) A CATDrawing with isolated views still has some links to 3D parts/product when running the File > Send To command Deletes the link
DOS: Drafting Operator Section DOS_0 (1) An unrelated document can be pointed to by a CATDrawing A section operator has an invalid link
DOS_1 (1) A section operator is not aggregated Deletes the object
GME: Generative Modeler GME_0 (1) An unrelated document can be pointed to by a CATDrawing Deletes the object
GME_1 (1) An unrelated document can be pointed to by a CATDrawing Deletes the invalid link
DRW: Drawing DRW_0 (1) (*) The document contains more than one drawing Deletes the unused drawings
DRW_1 (1) Ghost links when running the Edit > Links... command, or the size of a CATPart is abnormally big There is a DrwDrawing with external links in the CATPrtCont. It is not visible in the specification tree
DWE: Generative Drafting DWE_0 (1) An object managing links between the views and the 3D document points to an unrelated document Deletes the useless object
DWE_1 (3) Discrepancy between the number of linked documents when running File > Desk... and when running File > Send To Flags the view as not up-to-date and indicates that an update is required to perform the cleaning operation
DWE_2 (3) Discrepancy between the number of linked documents when running File > Desk... and when running File > Send To Replaces the internal links pointing to ghost documents by up-to-date links pointed to by the generative view's links
DWE_3 (3) Discrepancy between the number of linked documents when running File > Desk... and when running File > Send To Replaces the internal links pointing to ghost documents by up-to-date links pointed to by the generative view's links
DWS: Drawing Sheet DWS_0 (2) The views are not correctly organized in the sheet Reorders the views
DWS_1 (1) (*) The sheet is corrupted Deletes the sheet
DWV: Drawing View DWV_0 (1) (*) The view is corrupted or not correctly aggregated Deletes the view
DWV_1 (2) A view is linked to another CATDrawing Deletes the link
DWV_2 (2) Warning when opening a CATProduct Unplugs the view's sub-components with ghost links from their ghost reference and re-plugs them to their startups in the current document
DWV_3 (3) The local transformations of geometries in views (e.g. translations, scaling, rotations, offset) do not work, usually when some 2D component instances have been exploded or exposed in the CATDrawing The geometrical result of the axis component of a view has been lost
DWV_4 (3) The sketch support is in the No Show space Puts the sketch support in the Show space and puts its axis elements in the No Show space
DWV_5 (3) Ghost links when running the File > Send To command in a CATDrawing Removes the invalid link
DWV_6 (3) The size of the CATDrawing or the CATPart shows that some 2D Layout data is abnormally big Removes the useless geometrical results from the CGM container data
DWV_7 (1) Circles visible in previous releases (V5R12) are now invisible, or ellipses invisible in previous eleases (V5R12) are now visible Forces the open circles to be closed and deletes the ellipses in error. The circles are visible again
DWV_8 (3) Section Views is renamed to Front View with earlier Defined Front View seen as isolated No automatic Clean Action provided.  Manual clean is proposed.
DVM: Drawing View Make Up DVM_0 (2) Unused view make up Deletes the view make up
DWR: Drawing Relation DWR_0 (3) (*) An incoherent relation has been detected Deletes the useless DrwRelation
DWT: Drawing Pattern DWT_1 (3) A non aggregated pattern has been detected Deletes the pattern
GDI GDI_0 (1) Discrepancy between the number of linked documents when running File > Desk... and when running File > Send To Deletes the feature
GIE: Generated Item GIE_0 (2) Unused Generated Item Deletes the Generated Item
DAF: Drawing Area Fill DAF_0 (3) The area fill has no profile Deletes the area
DAF_1 (3) (*) The area fill is not aggregated Deletes the area
DAF_2 (3) (*) The area fill has a missing curve Deletes the area
DAF_3 (3) The area fill has no pattern Applies the default pattern
DAF_4 (1) A document contains area fills with ghost links to other documents Deletes the area fills
HLV: HLR View HLV_0 (1) A generative view is not aggregated Deletes the object
HLV_1 (1) The size of the CATDrawing is disproportioned compared to the data it contains Deletes the non aggregated generative view
HLV_2 (1) Ghost link when running the File > Send To command Deletes the link
HLV_3 (1) Ghost link when running the File > Send To command Deletes the link
HLV_4 (1) Ghost link when running the File > Send To command Deletes the link
HLV_5 (3) The associativity is lost for the definition of the breakout profile, section view profile, section-cut profile, auxiliary profile or for the modification of the graphic properties or, the removal of the Generated Items No clean available. For the auxiliary view: edits the section cut and replaces the profile. For the breakout: removes and re-draws it
STD: Standards STD_0 (2) Too many standards in the document Deletes the unused standards
STD_1 (2) The standard is not synchronized with the active sheet Re-synchronizes the standards
DET: Drawing Detail (2D component) DET_0 (3) A 2D component is not aggregated Deletes the component
DET_1 (3) A 2D component is not types through the interface Deletes the component
DET_2 (2) (*) The reference of a 2D component instance is outside its document Creates the reference in the same document and replaces the wrong reference
DET_3 (1) A 2D component instance has a too big or too small scale Deletes the scale
DET_4 (2) Redundant local reference in the model Redirects the instances of the redundant local reference to the correct one and removes the redundant local reference
DET_6 (1) Unpredictable behavior when using a drafting detail/ditto Deletes the invalid 2D component instance
DET_7 (2) Invalid link when opening  CATDrawing Unplugs the view's sub-components with ghost links from their ghost reference and re-plugs them to their startups in the current document
DET_8 (2) Ghost links when running the File > Send To command in a CATDrawing containing 2D component instances Modifies the link so that it points to the correct internal object
OLE: OLE Object OLE_0 (2) (*) The OLE object points to an invalid CATDrawing Replaces the OLE object by a new one
OLE_1 (1) Ghost links when running the File > Send To command Removes the useless OLE feature
DWG: Generative Dimension DWG_0 (1) The object managing the dimension generation is no more used Deletes the generative dimension
DWG_1 (3) The object managing the dimension generation is not aggregated Deletes the generative dimension
DWC: Callout DWC_1 (3) The callout is not aggregated Deletes the callout
DWC_2 (2) The callout arrows are visible even though the show attribute is set to CATNoShowAttr Resets the show attribute to CATShowAttr
DWA: Projected Axis DWA_1 (3) Object manufacturing cut views not aggregated Deletes the projected axis
DWH: Generative Pattern DWH_1 (3) The generative pattern is not aggregated Deletes the generative pattern
DWP: Pattern Mapping Table DWP_0 (3) The pointer for a pattern in 3D is no more used Deletes the object
DWP_1 (1) The pointer for a pattern in 3D is not aggregated Deletes the object
DAO DAO_0 (3) Associativity pointing to an external link with the document Deletes the associativity
DAO_1 (3) Ghost link due to a useless Drafting data referencing another document Deletes the useless data and its link
DAO_2 (2) The extension line is not visible (or not correctly) when creating an extension line for the roughness Takes the view scale into account for the extension line (overrun)
PIC: Drawing Picture PIC_0 (3) Non aggregated picture Deletes the picture
PIC_1 (2) The reframe on is infinite when opening a CATDrawing Modifies the picture position value (set at 0;0) and moves it to the No Show space
VWN: View Name VWN_0 (1) Ghost links when running the File > Send To command Deletes then rebuilds the formula to remove the external parameters
GPT: Generative Point GPT_0 (1) An unrelated document can be pointed to by a CATDrawing Deletes the object
SAC SAC_2 (1) Ghost link when running the File > Send To command Removes the Analysis connector containing the ghost link
LVW: Layout View LVW_1 (2) Ghost link when running the File > Send To command Unsets the View Filter attribute of the 2D Layout view with an external link
Unset the link between the 2DL section and the 2DL filter.
DFM: Drafting Format DFM_0 (2) When opening a document created in a previous version, the format of some sheets is flipped Computes and sets new values for the invalid attributes
LPR: L01 Product Profile LPR_1 (1) 2D Layout profiles are not updated when deleting a specific profile Unsets the View Filter attribute of the 2D Layout view with an external link
DTA: Drafting DTA_1(2) Table in an instanciated 2D Component does not keep its orientation. The table gets instantiated but the orientation is kept horizontal. The visualisation take into account the orientation of the table.
DTA_2(2) When opening the pre-CATIAV5R15 CATDrawing on any CATIA level other than the Drawing creation level, the table (width) becomes bigger. Restore valid value of margin.
  1. Annotation

Category Code Meaning Cleaner Action
DST: Simple Text DST_0 (1) Invalid simple text Deletes the text
DST_1 (1) Ghost link in an old CATDrawing containing a section view Removes the link but keeps the text as is
DST_2 (1) The number of annotations based on a simple text found by the search command is higher than the number of annotations based on a simple text seen by the user Deletes each annotation based on a simple text which is not displayed in the view
DST_3 (3) The annotation is not correctly displayed Modifies the annotation display to match the font size specification
DCR: Connector DCR_0 (2) Connector problem Retrieves the section specification in the related view
DCR_1 (3) Obsolete internal element for associativity Deletes the object
DCR_2 (1) Broken dimension or ghost link when running the File > Send To command in a CATPart The information about the associative dress-up (dimension, annotation, constraint, etc.) for assembly positioning has been lost
DCR_4 (3) The CATdrawing is abnormally big Deletes the useless elements
DCR_5 (1) When running the File > Send To command, a CATDrawing is linked to another CATDrawing Deletes the link
DCR_6 (1) When running the File > Send To command, a CATDrawing is linked to another CATDrawing Deletes the link
DCR_7 (2) Ghost link in a document pointing to a CATPart Updates the link
DCR_8 (2) When copy/pasting some geometries with their associated dimensions, some dimensions are missing Find the View missing connectors and add them to the View.
DCR_9 (2) When Drafting Threads are imported through FBDI/DBDI, the associativity to the 3D is lost The missing information is retrieved using another link and set on the internal component.
DCS: Drafting Constraint DCS_1 (2) Constraints which are not correctly aggregated are not taken into account Changes the place where the constraints are aggregated
DCS_2 (2) A link to a 3D connector has not been deleted after being isolated. Some annotations are displayed with a wrong status and the wrong colors because of an internal corrupted object Deletes each 3D connector that can be found in an interactive view. Fixes the link between the connector and the view aggregating the constraint
DCT: Container DCT_0 (1) Data model in V4 format is useless but is still stored Deletes the useless data
DCT_1 (2) Bad display of fonts, diameter symbol or no visualization of the datum feature Creates the missing feature for the annotations' visualization
DCT_2 (1) Ghost links when running the File > Send To command because of a non aggregated feature Deletes the non aggregated feature
DCT_3 (2) Dimensions and annotations cannot be built in the 2D Layout or FTA workbench. Some objects are not correctly updated Reinitializes the containers in error
DCT_4 (3) When opening a document, an error message indicates that the used font is not available even though this font is not used by any annotation Removes the reference to the font from the document
DCT_5 (2) Impossible to use new fonts on dimensions Removes the unused fonts from the list and adds a space in the list if needed
DDI: Dimension DDI_0 (2) An invalid dimension points to data Deletes the dimension
DDI_1 (1) A dimension points to another document Deletes the dimension
DDI_2 (1) (*) A constraint data is corrupted Deletes the dimension
DDI_3 (3) Non aggregated dimension Deletes the dimension
DDI_4 (2) The dimension display does not match the dimension properties Updates the dimension properties
DDI_5 (1) The number of dimension found by the search command is higher than the number of dimension that are displayed Deletes each dimension which is not displayed in the view
DDI_6 (1) Ghost link when running the File > Send To command Deletes the external link
DDI_7 (1) Ghost link when running the File > Send To command Deletes the external link
DDI_8 (1) Error when opening a CATDrawing Deletes the invalid link
DDI_9 (1) Error when opening a CATDrawing Deletes the invalid link
DDI_10 (2) Some radius dimensions are not correctly displayed Sets the invalid symbol mode to Automatic
DDI_11 (2) The dimension text does not use the right font Rebuilds the dimension visualization
DDI_13 (2) The dimension model defines some extension line interruptions which are not displayed Rebuilds the dimension in error so that they are displayed
DDI_14 (2) Parts of the dimension line are wrongly displayed Fixes the standard.
DDI_15 (2) The dimension position's value changes after an update Builds the dimension so that the position does not change anymore
DDI_16 (2) The dimension may use wrong format for tolerance display. The dimension visualization is updated in order to use the right tolerance format.
DDI_17 (2) The dimension may not display its before, after, upper and/or lower texts. The dimension visualization is updated in order to display the before, after, upper and/or lower texts.
DDI_18 (2) Fake Dimension may not display correctly the alphanumerical fake value. The dimension visualization is updated in order to display correctly the value.
DAC: Drawing Area cotation DAC_0 (1) Invalid dimension line Removes the dimension
  DAC_1 (1) The number of graphical dimensions found by the search command is higher than the number of graphical dimensions displayed Removes each graphical dimension which is not displayed in the view
DAC_2 (1) The annotation is not displayed in the drawing but when printed, it is displayed with a height equal to 10 Removes the annotation
DAC_4 (2) Changing the standard through Page Setup reverses the Roughness symbol Restores a correct orientation link
DCH DCH_0 (1) A constraint refers to an invalid 3D connector Removes the constraint
DCH_1 (2) A constraint has invalid elements Fixes the constraint
DCH_2 (2) (*) When running the File > Send To command, an isolated view is still linked to its part Removes each hybrid constraints which can be found in the interactive view
DTE DTE_0 (3) An internal drafting data erroneously references another document Removes the link
DTE_1 (2) Ghost link when running the File > Send To command Unsets the link
DTE_2 (2) A text with a position link to another text is not up-to-date after canceling the text edition of the reference, or the text leader with a positional link to a 2D line points to another element Updates the position link to get the correct position
  1. 3D Functional Tolerancing and Annotation

Category Code Meaning Cleaner Action
FTA: Functional Tolerancing & Annotation FTA_1 (1) (*) Some features in the TTRS (Technologically and Topologically Related Surface) container are not valid. The TTRS features become invalid because their start up has been removed from the container Removes the invalid TTRS features
FTA_2 (3) Some RGE (Reference Geometrical Elements) features are not used by any 3D annotations. Removes the unused RGE features
FTA_3 (3) Some TTRS features are not used by any 3D annotations. Removes the unused TTRS features
FTA_4 (3) When deleting FTA annotations, all Drafting internal entities are not deleted Removes all Drafting annotations which are not pointed by a FTA one.
FTA_5 (1) Ghost link problem when opening a document Removes the non aggregated 3D annotations
FTA_6 (1) Some FTA dimension features are abnormally located in the annotation set Removes the invalid drafting annotations and recreates the new topology
FTA_7 (3) Redundant geometrical element in a user surface Not fixable. Needs a manual correction
FTA_8 (2) A problem occurs during the CG thread status computation Modifies the feature attribute's value
FTA_9 (3) he FTA geometrical tolerance has an invalid status when its 3D display is not consistent with its semantic attribute Non fixable error
FTA_10 (3) The TTRS object used by the corrupted view comes from a different document. Data filtering of the document is be possible Creates a new correct TTRS feature on the axis system and sets it to the corresponding view
FTA_11 (2) When running the File > Send To command, there is an extra empty line among the documents to process Resets the invalid sequence
FTA_12 (3) No 3D annotation view has been found for a 3D annotation Creates a new FTA view and reroutes it to the FTA 3D annotation and the associated Drafting view
FTA_13 (3) When creating a new semantic datum target, the datum becomes invalid with the following diagnostic report \"target label unicity\" Removes the inconsistent datum target without any semantic datum associated
FTA_14 (3) A visualization dimension is linked to several dimensions or annotations Removes the invalid links between the visualization dimension and the linked dimensions
FTA_15 (3) Ghost links related to the FTA capture feature and pointing to non existing documents when running the File > Send To command Removes all the invalid external links in the captures
FTA_16 (3) Ghost link related to the NOA feature appear even if the pointing document is deleted Removes the invalid external link to the NOA feature.
FTA_17 (3) A NOA feature with a ditto created using CAA API CATINoa::SetDitto must be created on the drafting view of type Background View and not on the drafting view pointed to by the NOA feature. Compares the ditto's drafting view with the one of the retrieved drafting view of type Background View then, if there is a discrepancy, transfers the ditto to the correct view.
FTA_18 (3) Ghost links related to the FTA Text feature and pointing to non existing documents when running File > Send To command Removes the invalid external link of Text feature.
FTA_19 (3) Inconsistent Repetitive Feature Identifier. Changes the Inconsistent Repetitive Feature Identifier.
FTA_20 (3) After View from 3D command, dimensions are not generated in drawing. After View from 3D command, dimensions are generated in drawing.
  1. SheetMetal

Category Code Meaning Cleaner Action
UPD: Update UPD_1 (2) Invalid update stamp Sets the update to false
SHM: Sheet Metal SHM_0 (2) The element has no activity or no value Fixes the activity
SHM_1 (2) Internal BRep Edges features are pointed but not aggregated Aggregates the involved BRep Edge features
SHM_2 (2) Some functionality like Cutout, Hole, etc. fail Changes the invalid cylindrical transformation to a valid one
SHM_4 (2) Some Sheet Metal feature have a wrong link to Sheet Metal parameters Restores the link between the Sheet Metal feature and the Sheet Metal parameters
  1. Manufacturing

Category Code Meaning Cleaner Action
MFG: Manufacturing MFG_0 (1) The machining feature is not referenced by any activity; the unused machining feature is not deleted (activities cases) Deletes the unused machining feature
MFG_1 (1) The pattern definition is not referenced by any pattern usage; the unused pattern definition is not deleted (pattern cases) Deletes the unused pattern definition
MFG_2 (2) The body referenced by a manufacturing geometry in SMART NC mode is duplicated Deletes the duplicated body
MFG_3 (1) The tool path is not referenced by any activity Deletes the unused tool path
MFG_4 (2) Ghost link when running the File > Send To command in a machining resource Unsets the attribute on the machining resource
DMR: Digital Manufacturing Review DMR_1 (3) References to not found files appear when running the File > Send To command Considers Simulation Initial State objects as invalid if they point to objects that have been removed from the current document
DMR_2 (3) Ghost link when running the File > Send To command in CATProcess document The links pointing to another document are resolved to point to the corresponding product in the current document.
  1. Knowledge

Category Code Meaning Cleaner Action
KWE: Knowledge KWE_1 (1) The Knowledge object is not aggregated; bad performance when opening a document and a URL points to a document through an invalid attribute type Deletes the attribute. If the parameter is pointed to by a relation, adds the object to the parameter set; if the object is a relation, adds it to the relation set)
KWE_2 (1) A Knowledge relation in a CATPrtCont points to other documents Deletes the relation
KWE_3 (2) The output value of a relation is not consistent. After forcing the relation evaluation, its value changes Forces the evaluation
KWE_4 (2) A Knowledge check is broken. The "!" information is displayed and an error in the stream leads to an incorrect link in the check attributes Restores the links correctly
KWE_5 (2) A parameter external reference is synchronized with a wrong value Updates the value with the good one
KWE_8 (3) Ghost link between a parameter and a product when running the File > Send To command Modifies the parameter by removing the invalid link
KWE_1 (1) Ghost link between a relation set and a parameter when running the File > Send To command Removes instantiated relations from the relation set
URL_1 (3) (*) Bad performance when opening a document and a URL points to a document through an invalid attribute type Corrects the attribute type
  1. Kinematics

Category Code Meaning Cleaner Action
JNT: Joint JNT_1 (1) One or several kinematics joint axes are corrupted Deletes the corrupted joint
JNT_2 (1) One or several geometries pointed to by a kinematics joint are corrupted Deletes the corrupted joint
JNT_3 (1) There are several mechanism containers in the same CATProduct Deletes all the mechanism containers except the first non empty one
JNT_4 (2) The constraints associated to the joints of a mechanism are broken Replaces the incorrect pointed geometric element by a correct one
JNT_5 (2) A "Point on Curve" joint simulation is not correct Updates the internal frames of the joint
  1. Generic Naming

Category Code Meaning Cleaner Action
GNL: Generic Naming Link GNL_1 (3) The BRep feature points to a ghost document Deletes the link
GNL_3 (3) (*) BrpRsur, BrpWire, etc. are not aggregated Deletes BrpRsur, BrpWire, etc.
  1. New Topological Objects

Category Code Meaning Cleaner Action
FGM: Fat Geometry FGM_1 (3) The size of the part is abnormally huge as compared to the number of elements. Some vertices have unnecessary geometrical data (linked curves/surfaces and some surfaces are unnecessarily extrapolated). Removes the unnecessary geometrical data. The part is the same but with a smaller size.
If you update the CATPart, this error may re-appear again (after the cleaning rule).
If unextrapolated elements are finally extrapolated, the shape of extrapolation can be different from the original one: the extrapolated part of the element has been "cleaned", and the extrapolation can be different depending on the algorithm that generates it.
  1. Space Analysis

Category Code Meaning Cleaner Action
LIF: Product Lifecycle LIF_6 (1) (*) Some dimension are CATSpecObject_Broken Deletes the dimension and the measure
LIF_15 (1) Ghost link due to an invalid measure when running the File > Send To command Removes the input selection of the measure
LIF_16 (2) Ghost link due to an invalid measure inertia when running the File > Send To command Unsets the attribute selection of the measure inertia
  1. Part Design

Category Code Meaning Cleaner Action
BOL: Boolean BOL_0 (2) Visualization problem due to a Boolean between a solid body (old) and a hybrid body (new) Moves the invalid operand body under the part
BOL_1 (2) Visualization problems due to a Boolean between two hybrid bodies (new) Moves the invalid operand body under the part
BOL_2 (2) The solid body containing a Boolean feature is not processed when the part to part data filtering is done Deactivates then re-activates the invalid Boolean feature
BOL_3 (2) Detects old removed boolean operation (created on and after V5-6R2012) or adds boolean operation (created before V5-6R2014), where bodies with different polarity are involved. No clean possible
CPF: Part Design Feature CPF_0 (3) The size of a CATPart is abnormally huge compared to the number of elements Deletes the unreferenced BRep features
DRF: Draft DRF_0 (3) Faces to draft, fix aggregation of Brep Features Removes the Rsur Features from CGMBody to PartBody
DRF_1 (3) The default pulling direction is not compatible in the object and the vector Resets the pulling direction in the object and the vector
DVB: Default Value Bags DVB_0 (3) An applicative design table cannot be deleted A link to the design table is found even though no feature uses it
DVB_1 (3) Ghost link in a CATPart when running the File > Send To command Unsets the improper "Hole_StandardTable" attribute of DefaultValuesBag
FIL: Fillet FIL_0 (2) When editing a filter, the following error message is displayed: "Internal error in mechanical modeler" Moves the PointOnEdge (Fillet Radius object containing it) to the appropriate the ribbon
THD: Thread THD_0 (3) A link between a design table and the standard reference file is not broken Breaks the link
THD_1 (3) Changing the value of an external parameter does not update the Thread Description Forces the value change of the external parameter
THD_2 (2) Thread-Tap analysis shows thread with some standard description Useless TR thread description is unset
MIR: Mirror MIR_0 (2) One or several reference elements kept in the Generative Tool for mirroring are lost Creates again the reference elements kept in the Generative Tool
PAT: Pattern PAT_0 (1) The document cannot be updated Deletes the redundant instances in the Generative Tool of the user pattern
PAT_1 (2) Some instances of the rectangular pattern are lost after modifying the parameters of the occurrence feature Removes the incorrectly located instances and creates new instances at the right location regarding the pattern grid definition
PAT_2 (2) Selecting an edge/face of a circular pattern's instance (made of a user pattern) also selects the edge/face of another circular pattern's instance Ignores the confusion point when naming the user pattern's instances. The circular pattern's instances are now correctly named
PAT_3 (2) The resulting geometry of the user pattern is not displayed. Only the reference appears in the geometry Removes constraints with external geometry. Instances of the pattern are correctly located
PAT_4 (2) Some instances of the pattern are missing. Corrects the feature's plug in-out.
PAT_5 (2) The object to pattern attribute of RectPattern is not set properly. Corrects the object to pattern attribute.
FMP: Functional Molded Part FMP_1 (2) The divide part body thickness is not updated when the body thickness is changed Sets the shell dependency to match the divide
FMP_2 (2) The sibling feature is not updated when the features parameters are changed Makes the sibling flags consistent with the sibling pointer
FMP_4 (2) A functional feature using a "to-shell" length does not correct the track of the shell Changes the reference to the correct shape
FMP_5 (2) A functional feature using a "to-shell" length does no correct the shell Changes the reference to the correct shape
FMP_6 (2) A functional feature using a body thickness for its "wall" value is not updated when the body thickness is changed Changes the reference to the correct parameter
FMP_7 (2) A feature that can be shelled does not change its "wall" direction when the part's shell properties (wall direction: inward/outward) are changed Changes the reference to the correct parameter
FMP_8 (2) A functional modifier tries to modify the features of another part Remove from the list the targets that are not in the same functional body
FMP_9 (2) Impossible to update a part using a force update and the part is corrupted If necessary, creates the shell property feature with a zero wall thickness
FMP_10 (2) When modifying a limiting element, the functional fillet is not updated Changes the attribute quality. The limiting element attribute is now set to SP_IN
FMP_11 (2) Parent/Children shows abnormal relationships between FMP features from different functional sets Deletes useless Breps features
DEB: Delete Error Body DEB_0 (2) Ghost link when running the File > Send To command Removes the following improper external attributes: "listErrorGeom1" and "listErrorGeom2"
PSM: Prisme PSM_0 (2) Ghost link when running the File > Send To command Restores a valid symmetric relation between the first and the second limit of a prism
PSM_1 (2) Ghost link when running the File > Send To command Auto-numbering data reset.
HOL: Hole HOL_0 (1) The rule created in V5R17 on the Hole's activity parameter does not work correctly Copies the rule set on the parameter and sets the valid activity parameter. Deletes the invalid activity parameter
  1. Plant Ship Modeler

Category Code Meaning Cleaner Action
BST: Backup Start Up BST_0 (3) The Backup Start Up is not declared in the Psp product Declares the Backup Start Up
BDR BDR_0 (3) Invalid version of a 2D/3D modeling Removes the direct pointing to the schematic functions
  BDR_1 (3) The File > Send To command shows a Ghost link. A pointed document is erroneously referenced in File > Send To and is not visible in Edit > Links or File > Desk. Remove the part instance specific information for deleted part instance.
CDC: Cross Document Connection CDC_0 (1) An error message is displayed if an invalid version of a cross document connection exists Uses a publication to support the cross document connections
SCH: Schematic SCH_0 (3) The extension has a wrong update state Sets the update state to TRUE
SCH_1 (3) One of the extremity connectors of the route object (that is connected to itself) is not displayed Finds all the branch connections that connect the connectors belonging to the same object. Removes these connections as well as any unconnected branch connections in a route
SCH_2 (3) An annotation in error "jumps" at first move during a direct manipulation  
PSP: Plant Ship Modeler PSP_0 (3) You should not be able to set the Piping or Tubing specification attribute Resets the value of the specification attribute
PSP_1  (2) Some wire objects do not have any user defined attributes Updates the cable wires with the missing user defined attributes
PSP_2 (2) When opening a CATProduct containing objects with a broken derived attributes link, a warning message recommends to run the CATDUA V5 Resets the derived link for the derived attributes
PSP_3 (1) Ghost link when running the File > Send To command in a CATProduct Removes the invalid builder connections
  Ghost link when running the File > Send To command in a CATProduct in a Run and its related objects (e.g. a Line ID) Unsets the value of the old parameter which has the ghost link and removes it
PSP_4 (2) Ghost link when running the File > Send To command in a Run and its related objects (e.g. Line ID) Unsets the value of the old parameter which has the ghost link and removes it
  1. Equipment and Systems Arrangement

Category Code Meaning Cleaner Action
RSN: System Routing Segments an Nodes RSN_0 (2) Ghost link when running the File > Send To command Recreates a new parameter and deletes the old one with the ghost link
RSN_1 (2) Ghost link when running the File > Send To command Recreates a new parameter and deletes the old one with the ghost link
  1. V4 V5 Interoperability

Category Code Meaning Cleaner Action
FS4 FS4_1 (3) Some elements should not be in the container Deletion the unwanted extension
  1. Electrical

Category Code Meaning Cleaner Action
EHI: Electrical Harness Installation EHI_1(3) The flexible curve attributes are not correctly valuated Sets the flexible curve attributes to a correct valueb
EHI_2 (2) The display of the name of electrical harness features is given by the Reference Designator attribute value and is not NLS compatible Unsets the Reference Designator attribute value for the ranch and bundle segments
EHI_3 (2) (*) The electrical knowledge formula is not visible Recreates all the electrical formulas under the geometrical bundle with the correct formulas
EHI_4 (1) Bundle segments lead to an incorrect configuration if the minimum bend radius is smaller than the diameter. The Rib geometrical feature does not behave in a standard way
EHI_5 (2) The branch point positions are not coherent when editing the branch Reconnects the bundle segment extremities to the right points
EHI_6 (2) When a bundle segment diameter attribute is changed, the document is not updated. Fixes the broken relations between the Circle Radius and ElecDiameter
EHI_7 (2) Ribs or lofts are in a multibranchable but cannot be edited as branchable and cannot be seen as bundle segments in the branchable edition Reconnects the bundle segment to right branchable
EHI_8 (1) A bundle segment is missing in the specification tree Deletes the bundle segment
EHI_9 (1) When expanding the nodes of a multibranchable, a branchable does not have the node for a bundle segment. Deletes the corrupted branchables
EHI_10 (2) Ghost link when running the File > Send To command in a CATProduct Synchronizes the connector instance's attribute of "_Elec_GeoDefinition" (i.e. the value of the reference is reported on the instance)
EHI_11 (2) Error when adding or removing a branch point Recreates correct links between the branchable and the mechanical features
EHI_13 (2) The segment extremity is highlighted at the wrong location when selecting a bundle segment, or the bundle segments are geometrically overlapped inside a branchable Reconnects the segment extremities to the right geometrical points and updates the bundle segments.
EDL: Electrical Device Librarian EDL_1 (3) The electrical part document is modified when instantiated from a catalog Updates the electrical features in the part
EDL_2 (2) When trying to replace a device connected to other electrical elements by another one, the links are broken Publishes the unpublished connectors of an electrical connection point
EDL_3 (3) The positioning matrix of an internal splice inside a geometrical harness does not correspond to its 3D visualization Calculates and sets the internal splice positioning matrix using the link established between the internal splice and the bundle segment with the defined offset value
EDL_4 (2) Ghost link when running the File > Send To command Synchronizes the Electrical Device Connector instances' attribute of "_Elec_GeoDefinition"
EDL_5 (2) Certain types of electrical devices fail to get routed through Creates a missing connector on all concerned Electrical Device references
  1. DMU Fitting

Category Code Meaning Cleaner Action
UFC: Unresolved Fitting Catalog UFC_1 (2) When running File  >  Send To  >  Directory in a CATProcess, there is an invalid link to a DMU Fitting file Deletes the unwanted "Track" container
SHC: Shuttle Container SHC_1 (3) Performance issue when loading a CATPart Deletes the unwanted "Track" container
TRC: Track Container TRC_1 (3) When running File  >  Send To  >  Directory in a CATPart, the name of an invalid CATProduct is displayed Deletes the unwanted "Track" container
  1. Robotics

Category Code Meaning Cleaner Action
IGP: IGriP IGP_1 (1) Non aggregated Tag Connectors created on a constraint definition are deleted by the CATDUA V5 when processing the LIF_8 error Aggregates the floating Tag Connector with the Tag Group being its logical parent
IGP_2 (2) File > Send To Directory command shows references to not found files if the document contain joint targets in robot task Joint Target Objects are considered invalid if any of their attributes are pointing to objects in a different document.
IGP_3 (1) Taglist node available directly to the product node is not valid. Some how customer has the data with the Taglist node available directly to the Product node. Remove a Taglist available directly to the Product, and the TagGroup node is re-parented to the Product node.
IGP_4 (1) The SendTo command fails with the following message:
"At least one file is not saved on a file system (probably loaded from a database)".
Remove the additional robot task that is not visible.
DBG: Device Building DBG_1 (1) The reference product (name of the CATProduct file) was replaced by an earlier version that has incompatible or missing mechanism information. Regeneration of the feature extension and restoration of the values.
  1. Mold Design

Category Code Meaning Cleaner Action
TFC: Tooling Feature Corruption TFC_0 (2) When opening only a sub-product of a Tooling Assembly, some products that are not part of the loaded sub-product are also loaded Resets the pointing attribute to the first rank instance of the product
TFC_1 (2) A product takes a very long time to close Removes the duplicated links
TFC_2 (2) When opening only a sub-product of a Tooling Assembly, some products that are not part of the loaded sub-product are also loaded Resets to 0 all the attributes of the useless extensions (their complete removal is not possible)
TFC_3 (2) Copy/Paste operation fails Resets the Part Container UserID to its default value CATPrtCont
  1. Body in White

Category Code Meaning Cleaner Action
LIF LIF_14 (3) Ghost link when opening a CATProduct Deletes the unused Body in White object
LIF_17 (3) Ghost link when opening a CATProduct Unsets the invalid attribute on the Automotive BiW Fastening feature
LIF_18 (3) Ghost link when opening a CATProduct Unsets the invalid attribute on the Automotive BiW Fastening Joint Element feature instance
BIW_0 (1) The BIW Joint Body Definition Joined Contact Zones are not updated when the BIW Joint Definition is modified Rebuilds the link between the BIW Joint Body and the BIW Joint
  1. Camera

Category Code Meaning Cleaner Action
CAM: Camera CAM_2 (1) Applicative cameras disappear and ghost links might appear when running the File > Send To command Instantiates a new camera with the SpecObject_broken data
  1. Scene

Category Code Meaning Cleaner Action
SCE: Scene SCE_0 (3) Ghost links when running the File > Send To command Deletes the useless scene feature
  1. Technological Result

Category Code Meaning Cleaner Action
TER: Technological Result TER_0 (2) The update status of the Technological Result node does not change when adding/modifying a feature in the body Re-plugs the invalid TROutput to the last shape feature (or its ResultOut) of the tool in which it has been created
TER_4 (2) The Technological results are missing under the mechanical tool Updates the feature generating lacking technological results
TER_5 (2) The Technological results node is created but it does not contain any item The naming issue related to transformation feature that prevents the creation of technological results items is corrected.
  1. Power Copy

Category Code Meaning Cleaner Action
PWC: Power Copy PWC_0 (1) Error in save process when a CATPart containing a Power Copy reference is imported in V6/3DEXPERIENCE, through FBDI. Deletes all the Power Copies pointing to an external document
  1. SFM (Structure Functional Modeler)

Category Code Meaning Cleaner Action
SFM: SFM (Structure Functional Modeler) SFM_1 (2) The stiffener created via a Copy/Paste on a new plate is out of date when the original plate is modified Replaces the link to the original plate by a link to the plate containing the corrupted stiffener
SFM_2 (2) During the instantiation of the Beam on curve via a Power Copy, the support of the Beam is not replaced Replaces the link to the selected curve by a link to the IntDisconnect
SFM_3 (2) Drawings are not generated for some stiffeners. Enforces the parent category on the child category
SFM_4 (2) After running CATDUA, Geometrical sets are created corresponding to Internal faces of Profile used in Built-it Slot. Deleting these Geometrical sets impacts Slot's and corrupt the model. There is no change in end user view. Document needs to be updated.
  1. PMD (Process Modeler)

Category Code Meaning Cleaner Action
PMD: Process Modeler PMD_1 (3) Some external resources (reference product) in a CATProcess may not be present in the resource context container Removes the useless entries in the container and adds the needed entries extracted from the resource list
PMD_2 (3) Some external product (reference product) in a CATProcess may not exist in the product context container. Moreover, certain entries in the container may have no corresponding instances in the PPR tree referring to them Removes the useless entries in the container and adds the needed entries extracted from the product list to the container
PMD_3 (3) A warning message informs you that some feature files are missing Removes the reference to the missing feature file
PMD_4 (2) Cutting, copying or pasting legacy activities of some simulation types may cause unexpected links to be displayed when running the Edit > Links... command Re-assigns improperly assigned items to the right attributes
PMD_5 (3) When opening the process document, the user sees error regarding missing process catalog(s). Links to missing process catalog(s) are removed from the process document.
  1. Mechanism

Category Code Meaning Cleaner Action
MEC MEC_1 (1) When opening a product containing a mechanism and when running File > Send To > Directory, extra components are displayed even if they are not in the model Deletes the corrupted imported mechanism and imports it again from the reference mechanism. If the mechanisms is at root product level, it is deleted
  1. DELMIA D5

Category Code Meaning Cleaner Action
D5I D5I_0 (3) Broken document link for a D5 part (DNBD5Part feature) representation.
Ghost link when running the File > Send To command.
Removes the dangling shape representations.